THE 2-MINUTE RULE FOR DP50RB

The 2-Minute Rule for Dp50rb

The 2-Minute Rule for Dp50rb

Blog Article

Aid 4D probe; figure out the probe by way of the ID code; change the 4D generate signal by way of the  electrical relay to create the 4D probe perform Typically. 4.2.2 Major board The key board might be divided into two areas: entrance-end of the main board and back again-finish of the primary board.

1.2.2 Warning Labels Warning Labels Meaning Please very carefully read through this guide in advance of use system. The next labels undoubtedly are a. Never put the device over a sloped area. Otherwise the available if the technique system may slide, causing personalized harm or even the machine functions with the cellular malfunction.

Don't use any cables aside from the cables supplied While using the machine by Mindray. three. Use the cable offered with This method to attach the printer. Other cables might lead to electric shock. Web page fifteen: Mechanical Security

3. Click on the higher icon in the monitor (prompts “Update” if you set the cursor on it), the update step is carried out, if fails, you should send out to R&D Middle. Determine 6-one Most important Check Servicing Display screen 4. After update is successful, restart the machine immediately after power off to create the information productive. HDD Partition ... Webpage ninety one structured report associated data file and DICOM viewing program Report report template obd.bin OBD information file Model.txt Model file Remark Remark file AnatomyImage Anatomical visuals Measurement Measurement library Doppler system and similar boot configuration main file and plug-ins, remote desktop server Multilanguage string file exe videoplay.

Permits usage of several scanned angles to form one image, leading to Increased distinction resolution and improved visualization

Slash off cable ties connecting the leading device around the Screen by diagonal slicing pliers, and then pull out the corresponding cable plugs.

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi detail mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

Mindray’s new era of black & white ultrasound program, DP-fifty Qualified, is supplied with State-of-the-art imaging technologies allowing further penetration and more rapidly image acquisition with higher resolution.

This handbook may referring to facts protected by copyright or patents and will not convey any license under the patent rights or copyright of Mindray, or of Some others. Web page 9: Assertion

The chapter materials the method to verify key perform and overall performance of solution. This can be only useful for reference, not preventive execution. Functionality checking and testing of the section shall be carried out by Mindray service engineers plus the consumer jointly. Web page sixty six: Normal Test

Observe: To the check, the brightness adjustment comes before distinction. Following readjusting the monitor’s contrast and brightness, Dp50rb adjust all preset and peripheral settings.

Take note: Prior to inserting the connector into the probe port, inspect the connector pin. When the pin is bent, usually do not use the probe until finally it has been inspected / fixed / changed. Putting in Peripherals To the versions on the supported peripherals, remember to confer with “2.

Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.

Effectiveness Take a look at 5.five.1 Exam Process Resolution Detection depth Geometric Posture Precision Blackout location test Record the Test illustrations or photos 5.five.2 Take a look at Information The picture used Here's just for reference, persist with the picture outcome in the true NOTE: condition. Demands: Show: set the distinction and brightness with the scientific application value (or perhaps the default position) Procedure ecosystem: dark area, simulating the medical software environment. Website page 76 In affliction which the transverse resolution tests targets are horizontally displayed, document the nominal distance of two targets that could be Plainly regarded. Repeat the Procedure earlier mentioned with the transverse resolution tests targets at other depths. As revealed in determine below. Axial resolution ... Web page seventy seven When utilizing the convex probe, keep the transverse resolution testing targets to notice: be shown close to the midline. When using a linear probe with steer purpose, do not turn on the steer operate when accomplish the transverse resolution check. Zoom in the area where by the targets Positioned if necessary. The diameter on the goal stage at a certain depth is equal for the transverse resolution within the depth. Web site 78 5.

A smart new form, Improved mobility and convenient Procedure make DP-50 well suited for all scientific options.

5.2.three Geometric positioning accuracy Longitudinal geometric positioning precision  Examination Stage: Do changes as the best way in testing the utmost depth. Document the space by 20mm Every single segment to the longitudinal targets line using the measurement caliper; Pick out the value with the greatest mistake (to 20mm), work out the accuracy using the components under The measurement caliper ought to be positioned within the upper edge of the goal, Take note:... Webpage seventy nine Transverse geometric positioning precision  Check Phase: Cover the scan surface area of your phantom with water or couple gel, gently Speak to the probe with the scan surface Alter the depth, earning the transverse targets to become shown while in the graphic. Regulate the main target point for being posited beside the transverse targets (the common just isn't apparent) Regulate parameters like attain, TGC, making each transverse targets to be Evidently shown. Webpage eighty 5.five.2.four Blackout Space Take a look at Phase: Include the scan area with the phantom with drinking water or couple gel, Carefully Make contact with the probe Together with the scan surface Change the depth at a decreased worth, and established the focus at the nearest destination to the scan surface area. Minimize the value of parameters like AP, Attain until eventually the background sound just can be viewed. Web page eighty one: Software Update And Routine maintenance

Report this page